Compiler Settings for Visual C++ 8.0 and Later Open Applications (Unmanaged Code)

Applies to TestComplete 14.0, last modified on January 23, 2019

This topic explains how to compile Visual C++ (unmanaged) and Qt applications in Microsoft Visual Studio 2005 - 2017 to prepare them for testing with TestComplete.

Note: The screenshots below were made in Visual Studio 2008.
  1. Open your Visual C++ project in Visual Studio 2005 - 2017.

  2. (Optional). To keep your release configuration intact, choose Build | Configuration Manager and select another configuration, say, Debug, as active for the project.

    Configuration Manager

    If you want to test the Release configuration, you can skip this step, but remember to restore the compiler settings after the testing is over.

  3. Open the project properties. To do this, right-click the project in the Solution Explorer and select Properties from the context menu.

  4. To provide TestComplete with information about internal methods and properties of MFC objects, you need compile the application with run-time type information (RTTI). To do this, select the Configuration Properties | C/C++ | Language category and set the Enable Run-Time Type Info option to Yes.

    Project Properties: Language property page
  5. A Visual C++ application can be “open” to TestComplete with wrapper classes for MFC or with both wrapper classes and Debug Info Agent™ (see Testing Visual C++ Applications - Overview).

    If you are going to “open” the application using wrapper classes, then you are done with the settings. Simply re-compile the application (Step 7).

    If you are going to use the Debug Info Agent™, then you need to compile your application with both run-time type information (RTTI) and debug information. We included RTTI at the previous step. To include debug info in the application, follow these steps:

    • In the project properties, select the Configuration Properties | C/C++ | General category and set the Debug Information Format option to either Program Database (/Zi) or Program Database for Edit and Continue (/ZI).

      Project Properties: General property page
    • If your application contains MFC CGridCtrl controls and you use the Win32 Release configuration, select the Configuration Properties | C/C++ | Optimization category and set the Whole Program Optimization option to No.

    • Select the Configuration Properties | Linker | Debugging category and set the Generate Debug Info option to —

      • Generate Debug Information (/Debug) in Visual Studio 2010 - 2017

      • Yes (/DEBUG) in earlier versions of Visual Studio

      Make sure the Generate Program Database File option specifies a valid path to the file that will hold debug information.

      Project Properties: Debugging property page
    • Select the Configuration Properties | Linker | Optimization category and set the Enable COMDAT Folding option to one of the following values:

      • Visual Studio 2010 - 2017: No (/OPT:NOICF).

      • Visual Studio 2008 or 2005: Default or Do Not Remove Redundant COMDATs (/OPT:NOICF).

      Project Properties: Optimization property page
  6. If your application uses MFC classes, switch to the Configuration Properties | General page and specify whether you want to use MFC in static or shared DLLs in the Project Defaults | Use of MFC combo box:

    Project Properties: General property page
    If you use the Use MFC in a Shared DLL option, you need to:
  7. Re-compile your application.

When your application is ready for the final delivery, remember to compile it without debug information and RTTI to reduce the application size.